Item
|
Servo amplifier
MR-J3- |
40A
|
|
Power supply
|
Voltage/frequency
|
3-phase or 1-phase 200 to
230VAC, 50/60Hz
|
|
|
Permissible voltage fluctuation
|
3-phase or 1-phase 200 to
230VAC: 170 to 253VAC
|
|
|
Permissible frequency fluctuation
|
Within 5%
|
|
|
Power supply capacity
|
Refer to section 11.2
|
|
|
Inrush current
|
Refer to section 11.5
|
|
Control circuit
power supply
|
Voltage, frequency
|
1-phase 200 to 230VAC, 50/60Hz
|
|
|
Permissible voltage
fluctuation
|
1-phase 170 to 253VAC
|
|
|
Permissible frequency
fluctuation
|
Within ±5%
|
|
|
Input
|
30W
|
|
|
Inrush current
|
Refer to section 11.5
|
|
Interface power supply
|
Voltage
|
24VDC ±10%
|
|
|
Power supply capacity
|
(Note 1) 300mA or more
|
|
Control System
|
Sine-wave PWM control, current control system
|
|
|
Dynamic brake
|
Built-in
|
|